SciELO journals
Browse
1/1
6 files

Prospective evaluation of micropulse transscleral diode cyclophotocoagulation in refractory glaucoma: 1 year results

dataset
posted on 2019-09-11, 02:47 authored by Alessandro Adad Jammal, Danilo Campos Costa, José Paulo Cabral Vasconcellos, Vital Paulino Costa

ABSTRACT Purpose: To evaluate the effectiveness in intraocular pressure reduction and safety of micropulse transscleral diode cyclophotocoagulation in refractory glaucoma. Methods: We prospectively evaluated a case series of 21 eyes of 21 consecutive patients with refractory glaucoma treated with micropulse transscleral diode cyclophotocoagulation at 12-month follow-up. The total treatment time was at the discretion of the surgeon, considering baseline and target intraocular pressure and glaucoma diagnosis. Intraocular pressure, inflammation, visual acuity, and number of medications were monitored. Success was defined as intraocular pressure between 6 and 21 mmHg and/or 30% reduction from baseline intraocular pressure with or without the use of antiglaucoma medications. Visual acuity loss was defined as a loss of ≥2 lines of vision on the Snellen chart or a ≥2-level decrease in visual function in patients with nonmeasurable chart acuity. Results: The mean age was 61.04 ± 12.99 years, and 11 (52.4%) patients were male, with most (95%) patients showing low visual acuity at baseline (count fingers or worse). The mean intraocular pressure was 33.38 ± 15.95 mmHg, and the mean number of medications was 3.5 ± 1.1 at baseline. After 1, 3, 6, and 12 months, 76.19%, 57.14%, 55.56%, and 66.67%, respectively, of the patients were classified as treatment successes. Seven (33.3%) patients required new laser treatment and were considered treatment failures. The mean intraocular pressure reduction was 44.72% ± 29.72% in the first week and 41.59% ± 18.93% at the end of follow-up (p=0.006). The mean number of medications significantly dropped to 2.00 ± 1.7 at the 12-month visit (p=0.044). Complications included hypotony (4.8%), intraocular inflammation after 1 month (19%), and visual acuity loss (4.8%). Conclusions: Micropulse transscleral diode cyclophotocoagulation was safe and effective for reducing intraocular pressure in eyes with refractory and advanced glaucoma, with reduced need for ocular antihypertensive medication.

History

Usage metrics

    Arquivos Brasileiros de Oftalmologia

    Categories

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC