Ultrasound versus electromyography for the detection of fasciculation in amyotrophic lateral sclerosis: systematic review and meta-analysis

dataset
posted on 2020-04-22, 02:47 authored by Márcio Luís Duarte, Wagner Iared, Acary Souza Bulle Oliveira, Lucas Ribeiro dos Santos, Maria Stella Peccin

Abstract The objective of this study was to determine the diagnostic accuracy of ultrasound and electromyography for the detection of fasciculation in patients with amyotrophic lateral sclerosis and to compare detection rates between the two methods. By searching the Cochrane Library, MEDLINE, Excerpta Medica, and Latin-American and Caribbean Health Sciences Literature databases, we identified studies evaluating the diagnostic accuracy and fasciculation detection rates of ultrasound and electromyography. The Quality Assessment of Diagnostic Accuracy Studies, version 2, and RTI item bank tools were used for the evaluation of methodological quality. Ultrasound, for 10 s or 30 s, had a higher detection rate than did electromyography in all muscles evaluated. The overall detection rate (in patients) did not differ significantly between ultrasound for 10 s and ultrasound for 30 s. The accuracy of ultrasound for 10 s was 70% in muscles and 85% in patients. The accuracy of ultrasound for 30 s was 82% in patients. Ultrasound provided detection rates superior to those achieved with electromyography, independent of the examination time and muscles evaluated.